Comprehensive models of portable flue gas analyzer: TZH8TY2000 (condition-O2-CO-SO2-NO-H2S) Item: m163516
Details:
In addition to portable flue gas analyzers for measuring oxygen in the flue gas, sulfur dioxide, nitric oxide, nitrogen dioxide, carbon monoxide, carbon dioxide, hydrogen sulfide and other harmful gases, but also by measuring the flue gas temperature, dynamic pressure, static pressure to calculate the flue gas flow rate, flow, and various gas emissions. Meanwhile, the instrument was equipped with combustion efficiency test function for enterprises to improve energy efficiency to provide reliable data. For environmental protection, health, labor, safety supervision, research, education and other departments for the boiler, furnace flue gas emissions monitoring.
Main features:
* SMT technology, reliable quality
* Coefficient of excess air, combustion efficiency
• Sensor temperature / linear compensation
* Extract gas constant, measured value is more stable and accurate
* Measured NOx = NO + NO2 (optional)
* Carbon dioxide (CO2) can be calculated, can be measured (NDIR)
High-performance long-life gas sampling pumps, vacuum up 60Kpa
Automatic correct temperature / pressure, standard conditions of data read-only
• Robust housing, can be used in harsh environments
* Built-in battery work 8 hours straight
• Measurement units (ppm and mg/m3) free translation (without conditions)
Detailed parameters:
Range of parameters
Resolution
Error
Sampling flow
0.8-1.5 L / min
0.1 L / min
≤ ± 2.5%
Gas dynamic pressure
0-2000 Pa
1 Pa
≤ ± 2%
Static gas
-30.00-+30.00 KPa
0.01 KPa
≤ ± 4%
Meter before the pressure
-30.00-0.00 KPa
0.01 KPa
≤ ± 2.5%
Flue gas temperature
0-600 ℃ (scalable)
1 ℃
≤ ± 3 ℃
Flow Control Stability
≤ ± 2% (including the 180V-250V voltage changes, the resistance changes within the 3-6KPa)
O2 (optional)
0 ~ 25%
0.1%
Indication error: ≤ ± 5%;
Repeatability: ≤ 2%;
Response time: ≤ 90s;
Stability: 1 hour indication changes in ≤ 5%.
SO2 (optional)
0-5700 mg/m3
Maximum Overload 14000 mg/m3
1 mg/m3
NO (optional)
0-1300 mg/m3
Maximum Overload 6700 mg/m3
1 mg/m3
CO (optional)
0-5000 mg/m3
Maximum Overload 25000 mg/m3
1 mg/m3
H2S (optional)
0-300 mg/m3
Maximum Overload 1500 mg/m3
1 mg/m3
Data storage capacity
200 Group
Battery working time
8 hours (non-condensing)
Dimensions
340 × 260 × 135mm
Instrument noise
<60dB (A)
Weight
About 3.0 kg
Power consumption
<20 W
Uses: environmental protection, petrochemical, education, research, metallurgy
Categories: physical, chemical, non-destructive testing