For a variety of industry analysis of the boiler gas emissions, thermal analysis, combustion research
Both measured and calculated seven kinds of combustion parameters of gas and 18
Special Note O2 sensor battery life stability of the machine capacity and other equipment critical operating parameters
The modular design of the future independent of the overall measurement module for automatic calibration of sensors, measurement modules can be flexibly configured easily upgrade
Efficient, long life sensors and post-processing, auto-correct cross-interference
Infrared analysis module can measure the concentration of CO2 and up to 50% of the HC 10000ppm
Tight, effective and reliable protection system protects the sensor and internal components
The design for the site operators
In the field without moving the host, through a small portable handheld remote control and data lines needed to complete all of the features the host
Full charge time can work for more than eight hours without external power
The operator can set the sampling, printing and data acquisition cycle, can store up to 2000 group test results,
Not only for operators in the future inquiries can also be downloaded to a computer using software for analysis and reporting Fireworks
Technical Features
Project
Resolution Accuracy
Range
Measuring
O2
0.1%
-0.1% +0.2%
0 ~ 21%
CO
1ppm
+20 Ppm <400ppm
+5% <2000ppm
+10%> 2000ppm
0 ~ 10000ppm
SO2
1ppm
+5 Ppm <100ppm
+5%> 100ppm
0 ~ 5000ppm
NO
1ppm
+5 Ppm <100ppm
+5%> 100ppm
0 ~ 5000ppm
NO2
1ppm
+5 Ppm <100ppm
+5%> 100ppm
0 ~ 1000ppm
Flue gas temperature
0.1 ℃
+1 ℃
0 ~ 600 ℃
Ambient temperature
0.1 ℃
+1 ℃
0 ~ 50 ℃
Pressure
0.01mbar
+0.5%
0 ~ 150mbar
Calculate
CO2
0.1%
+0.3%
0 ~ 99.9%
NOx 1ppm
+5 Ppm <100ppm
+5%> 100ppm 0 ~ 6000ppm
Net temperature
0.1 ℃
+1 ℃
0 ~ 600 ℃
Efficiency
0.1%
+1.0% Of reading
0 ~ 99.9%
Over space factor
0.1%
+0.2%
0 ~ 2885.0%
Loss
0.1%
+0.2%
0 ~ 99.9%
CO/CO2
0.0001
+0.01
0 ~ 0.9999
Standard
Host 450mm x230mm x 300mm
Handheld 220mm x 55mm x120mm
Standard flue gas probe 350mm x 8mm catheter 5m
Charger Operation Manual
Weight 9.5Kg
Optional configuration
Infrared CO2 + HC analysis module
1000mm probe
1200 ℃ high temperature probe
Black smoke probe
Fireworks analysis software |
|
|
|
|